Iov006, Iov007 – Dell PowerEdge VRTX User Manual

Page 294

Advertising
background image

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

IOV006

Message

Incorrect IOV component firmware version.

Detailed
Description

The IOV subsystem is comprised of several entities whose firmware versions must be of the
same group. User should not update indiviual IOV ssystem sub-components.

Recommended
Response Action

Upload the latest firmware version

Category

Configuration

SubCategory

IOV = IO Virtualization

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

IOV007

Message

Chassis manager unable to allocate power of one or more PCIE adapters.

Detailed
Description

For each adapter assigned to server power is allocatted when the server is powered on. If the
only portion of the need power is availiable the Chassis manager will not power on servers
associated adapters.

Recommended
Response Action

Power off one or more blades thereby freeing power

Category

Configuration

SubCategory

IOV = IO Virtualization

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

294

Advertising