Enc event messages, Enc40, Enc1 – Dell PowerEdge VRTX User Manual

Page 211: 12 enc event messages

Advertising
background image

12

ENC Event Messages

ENC40

Message

A new enclosure was detected on

arg1

.

Arguments

arg1 =

controller name

Detailed
Description

The controller detected a new enclosure. This is due either to a hot plug of an enclosure, or a
power state change of an enclosure. In addition, this message is generated if the daisy chain
order of the enclosures changes.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

ENC = Storage Enclosr

Severity

Severity 3 (Informational)

Trap/EventID

4339

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC1

Message

arg1

was inserted.

Arguments

arg1 =

Enclosure Management Module Name

Detailed
Description

An Enclosure Management Module (EMM) has failed is inserted into the enclosure.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

ENC = Storage Enclosr

211