Cmc8514, Cmc8516 – Dell PowerEdge VRTX User Manual

Page 112

Advertising
background image

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8514

Message

Fabric mismatch is detected in the I/O Module

arg1

.

Arguments

arg1 =

iom slot name

Detailed
Description

This error may occur due to any of the following conditons 1) Invalid I/O Module and mezzanine
card configuration, where a newly installed I/O Modules fabric type and the resident
mezzanine cards fabric types do not match or are incompatible. 2) Invalid I/O Module and I/O
Module configuration, where a newly installed I/O Module has a different or incompatible
fabric type from an I/O Module already installed in the fabric.

Recommended
Response Action

Refer to Chassis Management Controller Users Guide for additional information.

Category

System Health

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

2545

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8516

Message

The I/O Module

arg1

did not boot within the expected time.

Arguments

arg1 =

iom slot name

Detailed
Description

The I/O module may have taken more time to boot than was expected or the I/O module did not
boot.

Recommended
Response Action

Verify the I/O Module is turned on using CMC Web Interface or RACADM CLI and retry the
operation. Otherwise, reinsert the I/O Module and retry the operation. If the problem persists,
contact technical support.

Category

System Health

112

Advertising