Hwc2015, Hwc5035 – Dell PowerEdge VRTX User Manual

Page 288

Advertising
background image

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

HWC2015

Message

The

arg1

is configured correctly.

Arguments

arg1 =

name

Detailed
Description

None.

Recommended
Response Action

No response action is required.

Category

System Health

SubCategory

HWC = Hardware Config

Severity

Severity 3 (Informational)

Trap/EventID

2331

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

HWC5035

Message

An over-temperature event detected on I/O module

arg1

.

Arguments

arg1 =

number

Detailed
Description

The I/O module over heated.

Recommended
Response Action

Do the following: 1) Make sure fans are installed and working correctly. 2) Check the
temperature sensor status for the chassis and make sure it is within the chassis operating
temperature range. 3) Reseat the I/O module to clear the over-temperature condition. If the
problem persists, contact the service provider.

Category

System Health

SubCategory

HWC = Hardware Config

Severity

Severity 1 (Critical)

Trap/EventID

2329

288