Pci1316 – Dell PowerEdge VRTX User Manual

Page 407

Advertising
background image

Detailed
Description

System performance may be degraded.

Recommended
Response Action

Cycle input power, update component drivers, if device is removable re-install the device at the
next scheduled service time.

Category

System Health

SubCategory

PCI = PCI Device

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PCI1316

Message

A bus uncorrectable error was detected on a component at bus

arg1

device

arg2

function

arg3

.

Arguments

arg1 =

bus

arg2 =

device

arg3 =

func

Detailed
Description

System performance may be degraded, or system may fail to operate.

Recommended
Response Action

Cycle input power, update component drivers, if device is removable, re-install the device.

Category

System Health

SubCategory

PCI = PCI Device

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

407

Advertising