Hwc5006 – Dell PowerEdge VRTX User Manual

Page 269

Advertising
background image

Arguments

arg1 =

name

Detailed
Description

CMC has old firmware and does not recognize the new device which has requested link tuning
information. After updating the firmware the CMC will recognize the device.

Recommended
Response Action

Update the CMC firmware. If the problem persists, contact support.

Category

System Health

SubCategory

HWC = Hardware Config

Severity

Severity 2 (Warning)

Trap/EventID

2330

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

HWC5006

Message

A failure is detected on

arg1

.

Arguments

arg1 =

name

Detailed
Description

None

Recommended
Response Action

Contact technical support. Refer to your product documentation to choose the contact method
that is convenient for you.

Category

System Health

SubCategory

HWC = Hardware Config

Severity

Severity 1 (Critical)

Trap/EventID

2329

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

269