Pwr8562, Pwr8563 – Dell PowerEdge VRTX User Manual

Page 577

Advertising
background image

Severity

Severity 1 (Critical)

Trap/EventID

8417

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8562

Message

Unable to power on the server

arg1

before power on timer expired.

Arguments

arg1 =

server number

Detailed
Description

Unable to power on the server before the power on timer has expired. This happens if the
server did not show power on status change within 30 seconds after the power on operation
was initiated. This issue may also occur when iDRAC is rebooting.

Recommended
Response Action

The Server may need more time to power on. Wait for ten seconds and check the power
status. If the server was not powered on, retry the operation. If the issue persists, remove and
reinsert the server, wait for the iDRAC to complete startup, and retry the operation.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8563

Message

Unable to turn on Server

arg1

due to I/O fabric inconsistency.

Arguments

arg1 =

server number

Detailed
Description

The Server identified in the message did not turn on due to a fabric mismatch between the I/O
Module and the Mezzanine card on the Server.

Recommended
Response Action

Make sure that the hardware comtibility between the I/O Module (IOM) and the Mezzanine
(Mezz) card is correct. Check the M1000e Hardware Manual for correct component
compatibility.

577