Fan0002, Fan0003 – Dell PowerEdge VRTX User Manual

Page 233

Advertising
background image

Severity

Severity 1 (Critical)

Trap/EventID

2153

LCD Message

Fan <number> RPM is outside of range. Check fan.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

FAN0002

Message

Fan

arg1

RPM is greater than the upper warning threshold.

Arguments

arg1 =

number

Detailed
Description

The fan is not performing optimally. The fan may be installed improperly or may be failing.

Recommended
Response Action

Remove and re-install the fan at the next scheduled service window. If the issue persists,
contact technical support. Refer to the product documentation to choose a convenient contact
method.

Category

System Health

SubCategory

FAN = Fan Event

Severity

Severity 2 (Warning)

Trap/EventID

2154

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

FAN0003

Message

Fan

arg1

RPM is greater than the upper critical threshold.

Arguments

arg1 =

number

Detailed
Description

The fan is not performing optimally. The fan may be installed improperly or may be failing.

Recommended
Response Action

Remove and re-install the fan. If the issue persists, contact technical support. Refer to the
product documentation to choose a convenient contact method.

233