CMC8534

Message

Unable to turn on the server

arg1

because the power requirement request exceeds the power

cap value.

Arguments

arg1 =

slot number

Detailed
Description

Unable to turn on the server specified in the message, because the available power is lesser
than the requested power.

Recommended
Response Action

In the CMC Web interface, verify the available power and server power requirements. If
sufficient power is available, retry the operation. Otherwise, increase the power cap value.

Category

System Health

SubCategory

CMC = Chassis Management Controller

Severity

Severity 2 (Warning)

Trap/EventID

2546

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8535

Message

Unable to turn on High Power Management for the server

arg1

Arguments

arg1 =

slot number

Detailed
Description

Unable to turn on the server specified in the message because of an internal CMC error.

Recommended
Response Action

Reboot CMC and retry the operation. If the issue persists, reseat the server and retry the
operation.

Category

Audit

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

8689

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

121