Amp0308, Amp0309 – Dell PowerEdge VRTX User Manual

Page 51

Advertising
background image

Category

System Health

SubCategory

AMP = Amperage

Severity

Severity 1 (Critical)

Trap/EventID

2177

LCD Message

Disk drive bay <name> current is outside of range. Contact Support

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

AMP0308

Message

Disk drive bay

arg1

current is greater than the upper warning threshold.

Arguments

arg1 =

name

Detailed
Description

Product documentation contains information on correct configuration. The failure could also
be caused by a faulty component or related cabling. System performance may be degraded.

Recommended
Response Action

Review system power policy, check system logs for power related failures, and review system
configuration changes.

Category

System Health

SubCategory

AMP = Amperage

Severity

Severity 2 (Warning)

Trap/EventID

2178

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

AMP0309

Message

Disk drive bay

arg1

current is greater than the upper critical threshold.

Arguments

arg1 =

name

Detailed
Description

Product documentation contains information on correct configuration. The failure could also
be caused by a faulty component or related cabling. System performance may be degraded.