Pwr8560, Pwr8561 – Dell PowerEdge VRTX User Manual

Page 576

Advertising
background image

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8560

Message

Unable to turn on I/O Module

arg1

due to insufficient chassis power.

Arguments

arg1 =

IOM slot name

Detailed
Description

Unable to turn on the I/O Module identified in the message due to insufficient chassis power.

Recommended
Response Action

Utilize the Chassis Management Controller (CMC) web interface to check available power and
I/O Module power requirements. If sufficient power is available, restart the CMC and retry the
operation. If sufficient power is not availble due to an insufficient number of PSUs, add
additional PSU(s) and reinsert the I/O Module.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 1 (Critical)

Trap/EventID

8417

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8561

Message

Unable to power on server

arg1

because of iDRAC communication issue.

Arguments

arg1 =

server number

Detailed
Description

The Chassis Management Controller is unable to communicate with the Server iDRAC service
processor and the server could not be powered on. This situation may occur when iDRAC is
rebooting.

Recommended
Response Action

Wait for three minutes and then retry the operation. If the issue persists, remove and reinsert
the server and wait for the iDRAC to finish restarting.

Category

Audit

SubCategory

PWR = Power Usage

576