Asr0101, Asr0102, Asr0103 – Dell PowerEdge VRTX User Manual

Page 63

Advertising
background image

ASR0101

Message

The OS watchdog timer reset the system.

Detailed
Description

The operating system or an application failed to communicate within the timeout period.
System was reset. (IPMI sensor type code 23h offset 01 - event 3:0 - 3h if booting 4h if running)

Recommended
Response Action

Check the operating system, application, hardware, and system event log for exception events.

Category

System Health

SubCategory

ASR = Auto Sys Reset

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

ASR0102

Message

The OS watchdog timer shutdown the system.

Detailed
Description

The operating system or an application failed to communicate within the timeout period. The
system was shutdown. (IPMI sensor type code 23h offset - 02h event 3:0 - 4h)

Recommended
Response Action

Check the operating system, application, hardware, and system event log for exception events.

Category

System Health

SubCategory

ASR = Auto Sys Reset

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

ASR0103

Message

The OS watchdog timer powered down the system.

63

Advertising