Cbl event messages, Cbl8500, Cbl8501 – Dell PowerEdge VRTX User Manual
Page 99: 6 cbl event messages
6
CBL Event Messages
CBL8500
Message
SAS cable
arg1
to expander
arg2
is not connected.
Arguments
•
arg1 =
cable id
•
arg2 =
expander id
Detailed
Description
SAS cables are not connected to the expander correctly.
Recommended
Response Action
Check whether or not the SAS cables are connected to the expander. Reconnect the cables
and rety the operation.
Category
Storage
SubCategory
CBL = Cable
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
CBL8501
Message
SAS cable
arg1
is connected to the incorrect expander.
Arguments
•
arg1 =
cable id
Detailed
Description
The SAS cable identified in the message is not connected to the correct expander.
Recommended
Response Action
Reconnect the SAS cable to the correct expander and retry the operation.
Category
Storage
SubCategory
CBL = Cable
99