Vdr50 – Dell PowerEdge VRTX User Manual

Page 883

Advertising
background image

Arguments

arg1 =

VD Name

Detailed
Description

A redundant virtual disk has lost redundancy. This may occur when the virtual disk suffers the
failure of more than one physical disk. In this case, both the source physical disk and the target
disk with redundant data have failed. A rebuild is not possible because there is no longer
redundancy.

Recommended
Response Action

Replace the failed disks and restore from backup.

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 1 (Critical)

Trap/EventID

4353

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR50

Message

Background Initialization (BGI) completed with uncorrectable errors on

arg1

.

Arguments

arg1 =

virtual disk

Detailed
Description

The background initialization task encountered errors that cannot be corrected. The virtual
disk contains physical disks that have unusable disk space or disk errors that cannot be
corrected.

Recommended
Response Action

Review other messages to identify whether the physical disk that has errors. If the virtual disk
is redundant, you can replace the physical disk and continue using the virtual disk. If the virtual
disk is non-redundant, you need to recreate the virtual disk after replacing the physical disk.
After replacing the physical disk, run a consistency check to verify the data.

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 1 (Critical)

Trap/EventID

4353

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

883