Tmp event messages, Tmp8500, Tmp8501 – Dell PowerEdge VRTX User Manual

Page 819: 44 tmp event messages

Advertising
background image

44

TMP Event Messages

TMP8500

Message

I/O Module

arg1

temperature exceeded operating range.

Arguments

arg1 =

iom slot name

Detailed
Description

The temperature of the I/O Module identified in the message has increased beyond the
operational range. Thermal protection shut down the I/O Module. Factors external to the I/O
Module may have caused this situation.

Recommended
Response Action

Check the chassis event log for fan issues and fix any issues present. If no fan issues are
detected, check chassis ambient temperature and make sure the temperature is within
operating range. Utilize the RACADM command "racadm getsensorinfo" to check the chassis
ambient temperature.

Category

Audit

SubCategory

TMP = Temperature

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

TMP8501

Message

Unable to read planar board temperature sensors. The cooling has been increased to
safeguard the system.

Detailed
Description

System was unable to read planar board or control panel temperature sensors. The fan speed
was increased to protect system hardware.

Recommended
Response Action

Remove AC power from the system and reapply AC power. Check to see if the issue is
resolved. If the issue persists, contact your service provider.

Category

Audit

SubCategory

TMP = Temperature

819

Advertising