Psu8503, Psu8504 – Dell PowerEdge VRTX User Manual

Page 510

Advertising
background image

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU8503

Message

The PSU in slot

arg1

detected 220 VAC input voltage and does not match chassis configuration.

Arguments

arg1 =

slot number

Detailed
Description

The input voltage of the PSU specified in the message does not match the input voltage of the
PSUs already present in the chassis.

Recommended
Response Action

Do the following: 1) Check if the input voltage of all the PSUs are the same. 2) If the input
voltage of the PSU specified in the message is not the same, then remove the unmatched PSU.

Category

Audit

SubCategory

PSU = Power Supply

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU8504

Message

The Allow 110 VAC Operation overload risk is not acknowledged.

Detailed
Description

Selecting the Allow 110 VAC Operation involves potential risk that an overload can occur. The
overload risk was not acknowledged in the CMC Web interface when the selection was made.

Recommended
Response Action

Select the Allow 110 VAC Operation and accept the subsequent dialog that acknowledges the
overload risk.

Category

Audit

SubCategory

PSU = Power Supply

Severity

Severity 3 (Informational)

510

Advertising