Bat event messages, Bat1000, Bat1011 – Dell PowerEdge VRTX User Manual

Page 67: 4 bat event messages

Advertising
background image

4

BAT Event Messages

BAT1000

Message

Battery on

arg1

is missing.

Arguments

arg1 =

controller name

Detailed
Description

The controller cannot communicate with the battery. The battery is absent or improperly
connected. A battery with a weak or depleted charge may also cause this message.

Recommended
Response Action

Verify that the device is present and then check the cables. See the storage hardware
documentation to verify cabling. In addition check the connection to the controller battery and
the battery health. A battery with a weak or depleted charge may cause this message.

Category

Storage

SubCategory

BAT = Battery Event

Severity

Severity 2 (Warning)

Trap/EventID

4274

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

BAT1011

Message

Battery on

arg1

is in warn only mode and requires reconditioning.

Arguments

arg1 =

Controller name

Detailed
Description

This alert is provided for informational purposes.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

BAT = Battery Event

67

Advertising