Psu0037, Psu0076 – Dell PowerEdge VRTX User Manual

Page 531

Advertising
background image

Recommended
Response Action

1) Remove and re-install the power supply. 2) Check cables and subsystem components in the
system for damage. 3) If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

Trap/EventID

2185

LCD Message

An over current fault detected on PSU <number>. Check PSU.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0037

Message

Fan failure detected on power supply

arg1

.

Arguments

arg1 =

number

Detailed
Description

None

Recommended
Response Action

Check for fan blockage. If not replace the power supply.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

Trap/EventID

2185

LCD Message

Fan failure detected on PSU <number>. Check PSU.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0076

Message

A power supply wattage mismatch is detected; power supply

arg1

is rated for

arg2

watts.

Arguments

arg1 =

number

arg2 =

value