Cmc8542, Cmc8543 – Dell PowerEdge VRTX User Manual

Page 124

Advertising
background image

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8542

Message

The CMC

arg1

was restarted because of a manual reset.

Arguments

arg1 =

slot id

Detailed
Description

The CMC specified in the message was manually restarted.

Recommended
Response Action

No response action is required.

Category

Audit

SubCategory

CMC = Chassis Management Controller

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8543

Message

The CMC

arg1

has reset because the thermal threshold was exceeded.

Arguments

arg1 =

slot id

Detailed
Description

The CMC specified in the message has reset becaused of thermal issues.

Recommended
Response Action

Do the following: 1) Review the Hardware Log and check if there are fans that are not
functioning properly. 2) Replace the fans that are not functioning properly. 3) If all the fans are
functioning, check the chassis temperature in the CMC Web Interface or by using RACADM.
When the fans are functioning properly and the chassis temperature is too high, the ambient
air temperture is too high or the air inlets are not receiving sufficient air.

Category

Audit

SubCategory

CMC = Chassis Management Controller

124