background image

CPU0700

Message

CPU

arg1

initialization error detected.

Arguments

arg1 =

number

Detailed
Description

System BIOS was unable to boot the processor.

Recommended
Response Action

1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

CPU = Processor

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

CPU <number> initialization error detected. Power cycle system

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

CPU0701

Message

CPU

arg1

protocol error detected.

Arguments

arg1 =

number

Detailed
Description

System event log and OS logs may indicate that the exception is external to the processor.

Recommended
Response Action

1) Check system and operating system logs for exceptions. If no exceptions are found continue.
2) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 3) Make sure the processor is seated correctly. 4) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

CPU = Processor

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

CPU <number> protocol error detected. Power cycle system

Initial Default.

FALSE