Iov002, Iov003 – Dell PowerEdge VRTX User Manual

Page 292

Advertising
background image

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

IOV002

Message

Unable to create or allocate the required resources.

Detailed
Description

The error occurs because of the following reasons: 1) The chassis manager is unable to
allocate required resources. 2) The chassis manager or chassis infrastructure firmware is
rolled back to an older version. 3) There is an internal communications problem between
chassis components.

Recommended
Response Action

Make sure the firmware for the various chassis components are compatible with each other. If
the firmware has been rolled back to a previous version, this error may occur. If this is the case
power down chassis; issue a racadm wipe command; power up chassis. If not the case power
cycle the chassis. If the problem persists, contact technical suport.

Category

Configuration

SubCategory

IOV = IO Virtualization

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

IOV003

Message

Unable to manage the device located in the PCIe slot specified in the operation.

Detailed
Description

A PCIe device error was detected that does not allow the assignment, unassignment, or the
turning off of the device. The errors can be caused by incorrect PCIe device installation. Only
Dell approved adapters are supported.

Recommended
Response Action

Make sure that supported adapters are used and installed correctly in the PCIe slots.

Category

Configuration

SubCategory

IOV = IO Virtualization

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

292

Advertising