Trap/EventID

4347

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR94

Message

Microcode update on

arg1

has timed out.

Arguments

arg1 =

physical disk

Detailed
Description

The attempt to update the physical disk has timed out. This may be due to too much activity on
the bus, a bad update package, or a bad disk.

Recommended
Response Action

Retry the update. The update utility may have already performed the retry operation.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 3 (Informational)

Trap/EventID

4347

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR95

Message

Microcode update on

arg1

has failed.

Arguments

arg1 =

physical disk

Detailed
Description

The attempt to update the physical disk has failed. This is due to too much activity on the bus, a
bad update package, or a bad disk.

Recommended
Response Action

Retry the update. If the update fails a second time, verify the update package is valid. If the
update package is valid, replace the failing disk. Contact technical support if the problem
persists.

Category

Storage