Pst0195, Pst0196 – Dell PowerEdge VRTX User Manual

Page 506

Advertising
background image

Trap/EventID

FALSE

LCD Message

Remote access controller configuration failed. Check screen message

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PST0195

Message

CPU configuration failed.

Detailed
Description

The current processor configuration is unsupported or encountered a fatal exception during
POST. Check the processor configuration. This exception occurred early in system power on,
thus the system may not display video. (BIOS POST exception code C3).

Recommended
Response Action

Review system processor configuration and reduce the system to the minimum configuration.

Category

System Health

SubCategory

PST = BIOS POST

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

CPU configuration failed. Check screen message

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PST0196

Message

Incorrect memory configuration.

Detailed
Description

System BIOS detected an invalid memory population. Reinstall the memory to match the
supported population. This exception occurred early in system power on, thus the system may
not display video. (BIOS POST Exception code C4)

Recommended
Response Action

Re-install memory to match supported memory configuration.

Category

System Health

SubCategory

PST = BIOS POST

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

Incorrect memory configuration. Review User Guide

506