Pdr47, Pdr48 – Dell PowerEdge VRTX User Manual

Page 451

Advertising
background image

Trap/EventID

4345

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR47

Message

A block on

arg1

was punctured by the controller.

Arguments

arg1 =

physical disk

Detailed
Description

The controller encountered an unrecoverable medium error when attempting to read a block
on the physical disk and marked that block as invalid. If the controller encountered the
unrecoverable medium error on a source physical disk during a rebuild or reconfigure
operation, it punctures the corresponding block on the target physical disk. The invalid block
clears on a write operation.

Recommended
Response Action

Back up the data from the disk. Start disk initialization and wait for it to complete, and then
restore the data from a backup copy.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 1 (Critical)

Trap/EventID

4345

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR48

Message

The

arg1

rebuild has resumed.

Arguments

arg1 =

physical disk

Detailed
Description

This message is generated after rebuild resumes on a physical disk.

Recommended
Response Action

No response action is required.

451