background image

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8545

Message

Detected a missing process failover condition detected. Process =

arg1

.

Arguments

arg1 =

process name

Detailed
Description

A firmware error has occurred causing a CMC failover. The process identified in the message
was not detected. The CMC will restart automatically.

Recommended
Response Action

No response action is required. If multiple failovers occur, contact your service provider.

Category

Audit

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8546

Message

Issues identified witrh Process

arg1

. Failover condition detected

Arguments

arg1 =

process name

Detailed
Description

A firmware error has occurred in the internal firmware process identified in the message. This
condition will cause a CMC failover to occur. If the issue persists, contact your service
provider.

Recommended
Response Action

No response action is required. A failover may result from this condition. If multiple failovers
occur, contact your service provicer.