Pst0143, Pst0192 – Dell PowerEdge VRTX User Manual

Page 504

Advertising
background image

Recommended
Response Action

Compare system memory installation to supported system memory configurations. Reduce
system configuration to minimum memory configuration.

Category

System Health

SubCategory

PST = BIOS POST

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

Memory initialization error. Contact support

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PST0143

Message

Intel Trusted Execution Technology (TXT) fatal error.

Detailed
Description

TXT boot failed. This could be related to memory errors or an error with the system TXT
configuration. A socketed TPM module may have been removed. This exception occurred early
in system power on, thus the system may not display video.

Recommended
Response Action

Check TPM presence. Remove and reapply input power. If the problem persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

PST = BIOS POST

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

Intel Trusted Execution Technology (TXT) fatal error. Contact support

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PST0192

Message

Shut-down test failed.

Detailed
Description

System BIOS shutdown test failed during POST. This exception occurred early in system power
on, thus the system may not display video. (BIOS POST exception code C0).

Recommended
Response Action

Check system event log for CMOS battery exceptions. Remove and reapply input power. If the
problem persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.

504