Pwr8564, Pwr8565 – Dell PowerEdge VRTX User Manual

Page 578

Advertising
background image

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 1 (Critical)

Trap/EventID

8417

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8564

Message

Unable to turn on the Server

arg1

because the power request exceeded the System Input Power

Cap.

Arguments

arg1 =

slot number

Detailed
Description

The server identified in the message was not turned on because the available power is less
than the requested power.

Recommended
Response Action

Utilize the Chassis Management Controller web interface to check the System Input Max
Power Capacity Power and server power requirements. If sufficient power is available, retry
the operation. Otherwise, increase the System Input Power Cap value.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

Trap/EventID

8418

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8565

Message

Unable to turn off the Server

arg1

due to iDRAC communication issue.

Arguments

arg1 =

server number

578