Vdr event messages, Vdr97, Vdr1 – Dell PowerEdge VRTX User Manual

Page 857: 46 vdr event messages

Advertising
background image

46

VDR Event Messages

VDR97

Message

Patrol Read corrected a media error on

arg1

.

Arguments

arg1 =

VD Name

Detailed
Description

The Patrol Read task has encountered an error such as a bad disk block and remapped data to
correct the error.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 3 (Informational)

Trap/EventID

4355

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR1

Message

arg1

failed.

Arguments

arg1 =

VD Name

Detailed
Description

A storage component such as a physical disk or an enclosure has failed. The failed component
may have been identified by the controller while performing a task such as a rescan or a check
consistency.

Recommended
Response Action

Replace the failed component. You can identify which component has failed by locating the
component that has a red "X" for its status. Perform a rescan after replacing the failed
component.

Category

Storage

SubCategory

VDR = Virtual Disk

857

Advertising