Pdr86, Pdr87 – Dell PowerEdge VRTX User Manual

Page 471

Advertising
background image

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR86

Message

Bad block table on

arg1

is full.

Arguments

arg1 =

physical disk

Detailed
Description

The number of blocks on the disk that exhibit an error has exceeded the capacity of the drive to
remap. Any future writes to bad sectors will be unrecoverable.

Recommended
Response Action

Replace the disk.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 2 (Warning)

Trap/EventID

4346

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

PDR87

Message

arg1

was reset.

Arguments

arg1 =

physical device

Detailed
Description

The physical device was reset. This is a normal part of operations and is not a cause for
concern.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

PDR = Physical Disk

Severity

Severity 3 (Informational)

Trap/EventID

4347

LCD Message

No LCD message display defined.

471