Pwr8544, Pwr8545 – Dell PowerEdge VRTX User Manual

Page 569

Advertising
background image

Recommended
Response Action

Turn on the server identified in the message. If the issue persists, contact your service
provider.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8544

Message

Chassis Management Controller turned off the Server

arg1

because of insufficient power at

inventory.

Arguments

arg1 =

slot number

Detailed
Description

Insufficient power is available for the server identified in the message to function. The server
will be turned off until there is sufficient power available.

Recommended
Response Action

Make sure there is enough power supply to distribute power. Using the CMC Web UI, go to
Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For
Allocation field view the available power. To add more power, insert more PSUs or remove
unused components from the chassis.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8545

Message

Chassis Management Controller turned off the server

arg1

because of incorrect power data

retrieved from iDRAC at inventory.

569