Psu0039, Psu0040 – Dell PowerEdge VRTX User Manual

Page 542

Advertising
background image

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0039

Message

An under current fault detected on power supply

arg1

.

Arguments

arg1 =

number

Detailed
Description

Insufficient amount of current to keep power supply operating at a normal levels.

Recommended
Response Action

1) Remove and re-install the power supply input cord. 2) Check power distribution or PSU input
source for anomalies. 3) If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

Trap/EventID

2185

LCD Message

Under current fault detected on PSU <number>. Check PSU.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0040

Message

An output under voltage fault detected on power supply

arg1

.

Arguments

arg1 =

number

Detailed
Description

The power supply output voltage is insufficient to keep system operating at a normal levels.

Recommended
Response Action

1) Remove the power supply input cord and then remove power supply. 2) Re-install the power
supply and then re-install the power supply cord. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

542