Vdr38, Vdr39 – Dell PowerEdge VRTX User Manual

Page 877

Advertising
background image

Trap/EventID

4355

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR38

Message

arg1

is renamed.

Arguments

arg1 =

VD Name

Detailed
Description

A user renamed a virtual disk. This alert is provided for informational purposes.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 3 (Informational)

Trap/EventID

4355

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR39

Message

The check consistency has made corrections and completed for

arg1

.

Arguments

arg1 =

VD Name

Detailed
Description

The virtual disk check consistency has identified errors and made corrections. For example,
the check consistency may have encountered a bad disk block and remapped the disk block to
restore data consistency. This alert is provided for informational purposes.

Recommended
Response Action

This Alert is for informational purposes only and no additional action is required. As a
precaution, monitor the Alert Log for other errors related to this virtual disk. If problems persist,
contact Dell Technical Support.

Category

Storage

877