Enc23, Enc24 – Dell PowerEdge VRTX User Manual

Page 223

Advertising
background image

ENC23

Message

arg1

Bad PHY

arg2

Arguments

arg1 =

Enclosure Name

arg2 =

args

Detailed
Description

There is a problem with a physical connection or PHY.

Recommended
Response Action

Contact the Dell Technical Support at support.dell.com.

Category

Storage

SubCategory

ENC = Storage Enclosr

Severity

Severity 1 (Critical)

Trap/EventID

4337

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC24

Message

Communication with

arg1

is intermittent.

Arguments

arg1 =

enclosure name

Detailed
Description

The controller is not receiving a consistent response from the enclosure. There could be a
firmware problem or an invalid cabling configuration. If the cables are too long, they degrade
the signal.

Recommended
Response Action

Power down all enclosures attached to the system and reboot . If the problem persists,
upgrade the firmware to the latest supported version. Verify the cable configuration is valid.
See the storage hardware documentation for valid cabling configurations.

Category

Storage

SubCategory

ENC = Storage Enclosr

Severity

Severity 1 (Critical)

Trap/EventID

4337

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

223