Vdr55, Vdr56 – Dell PowerEdge VRTX User Manual

Page 886

Advertising
background image

Severity

Severity 2 (Warning)

Trap/EventID

4354

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR55

Message

arg1

initialization has failed.

Arguments

arg1 =

VD Name

Detailed
Description

The controller cannot communicate with attached devices. A disk may be removed or contain
errors. Cables may also be loose or defective.

Recommended
Response Action

Verify the health of attached devices. Review the Alert Log for significant events. Make sure
the cables are attached securely. See the Cables Attached Correctly section for more
information on checking the cables.

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 1 (Critical)

Trap/EventID

4353

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR56

Message

Redundancy of

arg1

has been degraded.

Arguments

arg1 =

virtual disk

Detailed
Description

This message occurs when a physical disk in the disk group was removed or when a physical
disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses
mirrored or parity information) and only one physical disk has failed, the virtual disk can be
rebuilt. Typically, the virtual disk (E.g. RAID 6) has multiple redundant disks and there is a
problem with one of them.