7.1.5 garp timer hold

Command:

garp timer hold <timer-value>

no garp timer hold

Function:

Set the hold timer for GARP; the “no garp timer hold” command restores the default timer setting.

Parameter:

<timer-value> is the value for GARP hold timer, the valid range is 100 to 327650 ms.

Command mode:

Port Mode.

Default:

The default value for hold timer is 100 ms.

Usage Guide:

When GARP application entities receive a join message, join message will not be sent immediately.

Instead, hold timer is started. After hold timer timeout, all join messages received with the hold time

will be sent in one GVRP frame, thus effectively reducing protocol message traffic.

Example:

Set the GARP hold timer value of port 1/10 to 500 ms.

Switch(Config-If-Ethernet1/10)#garp timer hold 500

7.1.6 garp timer join

Command:

garp timer join <timer-value>

no garp timer join

Function:

Set the join timer for GARP; the “no garp timer join” command restores the default timer setting.

Parameter:

<timer-value> is the value for join timer, the valid range is 100 to 327650 ms.

Command mode:

Port Mode.

Default:

The default value for join timer is 200 ms.

Usage Guide:

GARP application entity sends a join message after join timer over, other GARP application entities

received the join message will register this message.