15 snmp-server group – PLANET WGSW-50040 User Manual

Page 62

Advertising
background image

Example:

Set current engine ID to A66688999F

Switch(config)#snmp-server engineid A66688999F

Restore the default engine ID

Switch(config)#no snmp-server engineid

1.4.15 snmp-server group

Command:

snmp-server group <group-string> {NoauthNopriv | AuthNopriv | AuthPriv} [[read

<read-string>] [write <write-string>] [notify <notify-string>]] [access {<num-std>|<name>}]

[ipv6-access {<ipv6-num-std>|<ipv6-name>}]

no snmp-server group <group-string> {NoauthNopriv | AuthNopriv | AuthPriv} [access

{<num-std>|<name>}] [ipv6-access {<ipv6-num-std>|<ipv6-name>}]

Function:

This command is used to configure a new group; the “no” form of this command deletes this group.

Command Mode:

Global Mode

Parameter:

<group-string> group name which includes 1-32 characters

NoauthNopriv Applies the non recognizing and non encrypting safety level

AuthNopriv Applies the recognizing but non encrypting safety level

AuthPriv Applies the recognizing and encrypting safety level

read-string Name of readable view which includes 1-32 characters

write-string Name of writable view which includes 1-32 characters

notify-string Name of trappable view which includes 1-32 characters

<num-std> is the access-class number for standard numeric ACL, ranging between 1-99;

<name> is the access-class name for standard ACL, the character string length is ranging between

1-32;

<ipv6-num-std> is the access-class number for standard numeric IPv6 ACL, ranging between

500-599;

<name> is the access-class name for standard IPv6 ACL, the character string length is ranging

between 1-32.

Usage Guide:

There is a default view “v1defaultviewname” in the system. It is recommended to use this view as

the view name of the notification. If the read or write view name is empty, corresponding operation

Advertising