11.3.3 Routing XIU Cables

XIU cables, IPN 600-1039-Gxx, are available in lengths of 15 ft. (4.6m), 30 ft.
(9.1m), 50 ft. (15.3m), and 100 ft (30.5m). The signals traveling on this cable are
both analog and digital. It is suggested that it not be routed near areas with high
levels of electromagnetic interference, even if its length must be somewhat
increased.

11.3.4 Interface Cable Fabrication and Pin-Out

It is necessary to fabricate several cables in order to interface the controller to the
deposition system. Refer to

section 11.2.3, Minimizing Noise Pickup From External

Cabling, on page 11-7

.

11.3.4.1 Source Control Connection

A digital to analog conversion (DAC) module, IPN 760-1112-G1, is included as
standard equipment with the controller. It provides 6 conversion channels. These 6
channels may be programmed for source control or chart recorder functions as
desired. The 6 connectors are BNC.