Drive (port 0) speed control file – Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 111

Advertising
background image

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

111

Drive Port 0 Parameters

Chapter 3

Drive (Port 0) Speed Control
File

Fil

e

Gr

oup

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta

T

yp

e

SPEED C

O

NTROL

Sp

ee

d L

im

it

s

520

Max Fwd Speed
Maximum Forward Speed
Sets the forward speed high limit. Refer to P524 [Overspeed Limit].

Units:

Default:

Min/Max:

Hz
RPM
P27 [Motor NP Hertz]
P28 [Motor NP RPM]
Based on [Motor NP Hertz]/[Motor NP RPM]
and Voltage Class / [Motor NP Hertz] x 16.00
Based on [Motor NP Hertz]/[Motor NP RPM]
and Voltage Class / [Motor NP RPM] x 16.00

RW Real

521

Max Rev Speed
Maximum Reverse Speed
Sets the reverse speed high limit. Refer to P524 [Overspeed Limit].

Units:

Default:

Min/Max:

Hz
RPM
P27 [Motor NP Hertz] x –1.00
P28 [Motor NP RPM] x –1.00
[Motor NP Hertz] x –16.00 / 0.00
[Motor NP RPM] x –16.00 / 0.00

RW Real

522

Min Fwd Speed
Minimum Forward Speed
Sets the low limit for speed reference after scaling is applied. Refer to P524 [Overspeed
Limit].

Units:

Default:
Min/Max:

Hz
RPM
0.00
0.00 / [Motor NP Hertz] x 16.00
0.00 / [Motor NP RPM] x 16.00

RW Real

523

Min Rev Speed
Minimum Reverse Speed
Sets the low limit for speed reference after scaling is applied. Refer to P524 [Overspeed
Limit].

Units:

Default:
Min/Max:

Hz
RPM
0.00
[Motor NP Hertz] x –16.00 / 0.00
[Motor NP RPM] x –16.00 / 0.00

RW Real

524

Overspeed Limit
Overspeed Limit
Sets the incremental amount of the output frequency (above maximum speed: either
P520 [Max Fwd Speed] or P521 [Max Rev Speed]) allowable for functions such as slip
compensation.

Units:

Default:

Min/Max:

Hz
RPM
Based on P27 [Motor NP Hertz]/P28 [Motor
NP RPM] and Voltage Class
0.00 / (P27 [Motor NP Hertz] / 3)
0.00 / (P28 [Motor NP RPM] / 6)

RW Real

525

Zero Speed Limit
Zero Speed Limit
Establishes a band around zero speed that is used to determine when the drive considers
the motor to be at zero speed.

Units:

Default:

Min/Max:

Hz
RPM
P27 [Motor NP Hertz] x 0.001
P28 [Motor NP RPM] x 0.001
Based on P27 [Motor NP Hertz]/P28 [Motor
NP RPM] and Voltage Class

RW Real

Frequency

Voltage

Overspeed

Limit

Frequency Trim due to
Speed Control Mode

Max Volts

Motor Volts

Run

Break Volts

Start Boost

Allowable Output Frequency Range -

Normal Operation

Allowable Speed Reference Range

Allowable Output Frequency Range -

Bus Regulation or Current Limit

Max

Freq

Motor

Hz

0

Break

Frequency

Max

Speed

Min

Speed

Output

Freq Limit