162

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Chapter 3

Drive Port 0 Parameters

DIA

G

N

O

STICS

Sta

tus

945

At Limit Status
At Limit Status

RO

32-bit
Integer

Status of dynamic conditions within the drive that are either active or a limit is being applied.

Bit 0 “Current Lmt” – Scalar current limit is adjusting the output frequency
Bit 1 “Bus Vltg Lmt” – Scalar bus voltage limit is adjusting the output frequency
Bit 2 “MaxSpeed Lmt” – Motor speed reference is limited to maximum forward speed or maximum reverse speed. See P520 [Max Fwd Speed], P521 [Max Rev
Speed].
Bit 3 “OverSpd Lmt” – Motor speed reference positive (+) trim is at maximum speed limit plus or minus (+/-) the overspeed limit
Bit 4 “Spd Reg Lmt” – The output of the drive’s speed regulator has reached limit. See P655 [Spd Reg Pos Lmt], P656 [Spd Reg Neg Lmt].
Bit 5 “Freq Hi Lmt” – Scalar control inner ramp high limit is active
Bit 6 “Freq Lo Lmt” – Scalar control inner ramp low limit is active
Bit 7 “FreqOSPosLmt” – Scalar control inner ramp positive (+) overspeed limit is active
Bit 8 “FreqOSNegLmt” – Scalar control inner ramp negative (-) overspeed limit is active
Bit 9 “Flux Braking” – Flux braking is active
Bit 10 “Economize” – Economize is active
Bit 11 “PWM FreqLmt” – PWM frequency is reduced by the thermal regulator
Bit 12 “DB Res Limit” – Dynamic brake thermal protection is active. Verify P385 [DB ExtPulseWatts].
Bit 13 “PsnReg LoLmt” – The position integrator low limit is active
Bit 14 “PsnReg HiLmt” – The position integrator high limit is active
Bit 15 “PsnReg LoSpd” – The position regulator output (speed) is at low limit
Bit 16 “PsnReg HiSpd” – The position regulator output (speed) is at high limit
Bit 17 “TrqCurPosLmt” – The torque current positive limit is active
Bit 18 “TrqCurNegLmt” – The torque current negative limit is active
Bit 19 “FlxCurPosLmt” – The flux current positive limit is active
Bit 20 “FlxCurNegLmt” – The flux current negative limit is active
Bit 21 “Trq Pos Lmt” – The positive torque limit is active. See P670 [Pos Torque Limit].
Bit 22 “Trq Neg Lmt” – The negative torque limit is active. See P671 [Neg Torque Limit].
Bit 23 “Mtrng PwrLmt” – The motoring power limit is active. See P427 [Motor Power Lmt].
Bit 24 “Regen PwrLmt” – The regeneration power limit is active. See P426 [Regen Power Lmt].
Bit 25 “Cur Lmt FV” – The current limit parameter or analog Input current limit is active
Bit 26 “Therm RegLmt” – The thermal regulator torque limit is active
Bit 27 “BusVltgFVLmt” – The bus voltage regulator torque limit is active
Bit 28 “Mtr Vltg Lkg” – The Vds motor voltage limit is active
Bit 29 “TrqPrvPosLmt” – The torque proving positive torque limit is active
Bit 30 “TrqPrvNegLmt” – The torque proving negative torque limit is active
Bit 31 “Cur Rate Lmt” – The Iqs rate limit is active

946

Safety Port Sts
Safety Port Status

RO

16-bit
Integer

Indicates the port location of a valid feedback option for use with the Safe Speed Monitoring Option.

Fi

le

Grou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-W

ri

te

Da

ta

T

ype

Options

Cu

r R

ate

L

m

t

Tr

qP

rv

N

egLm

t

Tr

qP

rv

Po

sL

m

t

Mtr V

ltg

Lk

g

Bus

Vlt

gF

VLm

t

Th

er

m

R

eg

Lm

t

Cu

r L

m

t F

V

Re

ge

n Pwr

Lm

t

Mtrng P

w

rLm

t

Tr

q N

eg

Lm

t

Tr

q P

os

L

m

t

FlxC

ur

Ne

gL

mt

FlxC

ur

Po

sLmt

Tr

qC

ur

N

eg

Lm

t

Tr

qC

ur

Po

sL

m

t

Ps

nR

eg

H

iS

pd

Ps

nR

eg

Lo

Sp

d

Ps

nR

eg

H

iL

m

t

Ps

nR

eg

Lo

Lm

t

DB Re

s Limit

PWM F

reqLm

t

Ec

onomi

ze

Fl

ux Br

ak

in

g

Fre

qO

SN

eg

Lmt

Fre

qO

SP

os

Lmt

Fre

q L

o L

m

t

Fr

eq Hi

L

m

t

Sp

d Re

g Lmt

Ov

er

Sp

d L

m

t

MaxSpeed

Lm

t

Bus

V

ltg

L

m

t

Cu

rr

en

t L

m

t

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Condition False
1 = Condition True

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Po

rt

8

Po

rt

7

Po

rt

6

Po

rt

5

Po

rt

4

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Condition False
1 = Condition True