Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Chapter 3

Drive Port 0 Parameters

A

PPLI

CA

TION

S

Va

ri

ab

le

B

oo

st

1548

VB Current Rate
Variable Boost Current Rate
Output current rate of change.

Default:
Min/Max:

0.0
–/+1000.0

RO

Real

1549

VB Current Hyst
Variable Boost Current Hysteresis
Sets the hysteresis level around P1550 [VB Cur Thresh] for the variable boost voltage
function.

Default:
Min/Max:

0.0
–/+100.0

RW Real

1550

VB Cur Thresh
Variable Boost Current Threshold
Sets the P1548 [VB Current Rate] trigger level for the variable boost voltage function.
The trigger is not active until P1538 [VB Time] time has expired following a drive start.
P1535 [VB Config] Bit 2 “Rising Edge” = 0:
The value of [VB Current Rate] must first pass through [VB Cur Thresh] + P1549 [VB
Current Hyst] then [VB Cur Thresh] in order to cause a boost voltage trigger event.
P1535 [VB Config] Bit 2 “Rising Edge” = 1:
The value of P1548 [VB Current Rate] must first pass through [VB Cur Thresh] - P1549
[VB Current Hyst] then [VB Cur Thresh] in order to cause a boost voltage trigger event.

Default:
Min/Max:

–25.0
–/+1000.0

RW Real

1551

VB Rate Lag Freq
Variable Boost Rate Lag Frequency
Sets the lag (cutoff) frequency of the current magnitude low pass filter.
The output of this filter is displayed in P1548 [VB Current Rate].

Units:
Default:
Min/Max:

R/S
2.60
0.01 / 100.00

RW Real

Fi

le

Grou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-W

ri

te

Da

ta

T

ype

1560

See

page 131

.

Fil

e

Gr

oup

No.

Display Name
Full Name
Description

Values

Read-W

rite

Da

ta

T

yp

e

APPLIC

AT

ION

S

Sp

in

dl

e O

ri

en

t

Important: After the Spindle Orient group is set up for an application, any subsequent
changes to parameter settings will require a drive reset for the changes to take affect.

1580

SO Config

Spindle Orientation Configuration

RW 16-bit

Integer

Configures the options for the Spindle Orientation function.
Function requires P35 [Motor Ctrl Mode] is set to option 3 “Induction FV,” 6 “PM FV,” or 10 “IPM FV.” P125 [Pri Vel Fdbk Sel] and P135 [Psn Fdbk Sel] must also be set
up accordingly.

Bit 0 “Home DI” – Selects the type of Homing signal (Marker Pulse vs. Digital Input Switch). 1 = Home signal. 0 = Z Channel.
Bit 1 “Home DI Inv” – Rising/Falling Edge of Homing Input.
Bit 2 “Recap Hm Psnv” – Re-capture Home Position. Allows the drive to find Home after a power or drive reset. Typically set to 1 “Enabled.”
Bit 3 “ShortestPath” – Allow direction reversal to obtain shortest distance traveled.
Bit 4 “Scale Invert” – Inverts the calculation for the user-defined units value. This improves resolution as the value of P1587 [SO Cnts per Rvls] increases.

755

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Sc

al

e I

nv

er

t

Shor

te

stP

at

h

Re

ca

p H

m

P

sn

Ho

me

DI In

v

Ho

me

DI

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Disabled
1 = Enabled