Parameter / instance attribute mapping, Appendix e – Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 512

Advertising
background image

512

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Appendix E

Integrated Motion on EtherNet/IP

Parameter / Instance
Attribute Mapping

The following tables show the relationships between the Integrated Motion on
EtherNet/IP attributes and PowerFlex 755 parameters. If a parameter is not
listed, it is not accessible and its function is not be available.

Table 8 - PowerFlex 755 Drive Parameter Numeric Order

Drive

Integrated Motion

Parameter No.

Parameter Name

Base 10

Base 16

Integrated Motion on EtherNet/IP Instance

P1 Output

Frequency

600

258

Output

Frequency

P5

Torque Cur Fdbk

529

211

Iq Current Feedback

P6

Flux Cur Fdbk

530

212

Id Current Feedback

P7 Output

Current

601

259

Output

Current

P8 Output

Voltage

602

25A

Output

Voltage

P9 Output

Power

603

25B

Output

Power

P11

DC Bus Volts

620

26C

DC Bus Voltage

P12

DC Bus Memory

621

26D

DC Bus Voltage - Nominal

P20

Rated Volts

720

2D0

Inverter Rated Output Voltage

P21

Rated Amps

721

2D1

Inverter Rated Output Current

P22

Rated kW

722

2D2

Inverter Rated Output Power

P25

Motor NP Volts

318

13E

Motor Rated Voltage

P26

Motor NP Amps

319

13F

Motor Rated Continuous Current

P27

Motor NP Hertz

345

159

Induction Motor Rated Frequency

P28

Motor NP RPM

331

14B

Rotary Motor Rated Speed

P30

Motor NP Power

321

141

Motor Rated Output Power

P31

Motor Poles

329

149

Rotary Motor Poles

P36

Maximum Voltage

572

23C

Maximum Voltage

P37

Maximum Freq

573

23D

Maximum Frequency

P44

Flux Up Time

599

257

Flux Up Time

P60

Start Acc Boost

577

241

Start Boost

P61

Run Boost

578

242

Run Boost

P62

Break Voltage

575

23F

Break Voltage

P63

Break Frequency

576

240

Break Frequency

P65

VHz Curve

570

23A

Frequency Control Method

P73

IR Voltage Drop

47

2F

Induction Motor Stator Resistance

P74

Ixo Voltage Drop

348

15C

Induction Motor Stator Leakage Reactance

P75

Flux Current Ref

346

15A

Induction Motor Flux Current

P76

Total Inertia

496

1F0

Kj

P81

PM PriEnc Offset

561

231

Commutation Offset

P86

PM CEMF Voltage

341

155

PM Motor Rotary Voltage Constant

P87

PM IR Voltage

327

147

PM Motor Resistance

P88

PM IXq Voltage

328

148

PM Motor Inductance

P89

PM IXd Voltage

328

148

PM Motor Inductance

P95

VCL Cur Reg BW

554

22A

Kqp

P126

Pri Vel FdbkFltr

403

193

Feedback n Velocity Filter Taps

P155

DI Enable

960

3C0

Digital Input Configuration

P220

Digital In Sts

730

2DA

Digital Inputs

P305

Voltage Class

623

26F

Bus Voltage Select

Advertising