Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 239

Advertising
background image

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

239

Embedded Feature and Option Module Parameters

Chapter 5

Embe

dded EtherN

et/IP

81
82
83
84

Fr Peer Addr 1
Fr Peer Addr 2
Fr Peer Addr 3
Fr Peer Addr 4

From Peer Address 1…4
Sets the bytes in the IP address that specifies the device from which the adapter receives
(consumes) Peer I/O data.

Important: The Peer Inp Addr must be on the same subnet as the embedded EtherNet/
IP adapter.
Changes to these parameters are ignored when P85 [Fr Peer Enable] is “1” (On).
For detailed information on peer communications, refer to the PowerFlex 755 Drive
Embedded EtherNet/IP Adapter User Manual, publication 750COM-UM001.

Default:
Min/Max:

0
0 / 255

RW 32-bit

Integer

85

Fr Peer Enable

From Peer Enable
Controls whether Peer I/O input is operating. A value of 0 “Off” turns off Peer I/O input. A
value of 1 “Cmd/Ref” overrides the settings in Parameters P76 [DLs Fr Peer Cfg], P78
[Logic Src Cfg], and P79 [Ref Src Cfg] and automatically uses peer Datalink 01 as the
drive's present Logic Command and peer Datalink 02 as the drive’s Reference. A value of
2 “Custom” enables peer I/O input using the Datalink count and settings provided by the
user.
For detailed information on peer communications, refer to the PowerFlex 755 Drive
Embedded EtherNet/IP Adapter User Manual, publication 750COM-UM001.

Default:
Options:

0 = “Off”
0 = “Off”
1 = “Cmd/Ref”
2 = “Custom”

RW 32-bit

Integer

86

Fr Peer Status

From Peer Status
Displays the status of the consumed Peer I/O input connection.
For detailed information on peer communications, refer to the PowerFlex 755 Drive
Embedded EtherNet/IP Adapter User Manual, publication 750COM-UM001.

Default:
Options:

0 = “Off”
0 = “Off”
1 = “Waiting”
2 = “Running”
3 = “Faulted”

RO

32-bit
Integer

87

DLs To Peer Cfg

Datalinks To Peer Configure
Sets the number of drive-to-network Datalinks (parameters) that are used for Peer I/O.
The Datalinks being used are allocated from the end of the list. For example, if this
parameter's value is set to 3, Datalinks 14…16 are allocated for the three selected
Datalinks. The Datalinks allocated for this cannot overlap with other assigned DL To Net
01…16 parameters.
For detailed information on peer communications, refer to the PowerFlex 755 Drive
Embedded EtherNet/IP Adapter User Manual, publication 750COM-UM001.

Default:
Min/Max:

0
0 / 16

RW 32-bit

Integer

88

DLs To Peer Act

Datalinks To Peer Action
Displays the value of P87 [DLs To Peer Cfg] at the time the drive was reset. This is the
number of actual drive-to-peer Datalinks that the drive is expecting.

Default:
Min/Max:

0
0 / 16

RO

32-bit
Integer

Fi

le

Grou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-W

ri

te

Da

ta

T

ype

755

755

755

755

255 . 255 . 255 . 255

[Peer Inp Addr 1]

[Peer Inp Addr 2]

[Peer Inp Addr 3]

[Peer Inp Addr 4]

755

755

755

755

Advertising