940

Drive OL Count
Drive Overload Count
Indicates power unit overload (IT) in percentage. When the value reaches 100%, the
power unit overload fault occurs.

Units:
Default:
Min/Max:

%
0.00
0.00 / 200.00

RO

Real

941

IGBT Temp Pct
Insulated-Gate Bipolar Transistor Temperature Percent
Indicates IGBT junction temperature in percentage of the maximum junction
temperature.

Units:
Default:
Min/Max:

%
0.00
–/+200.00

RO

Real

942

IGBT Temp C
Insulated-Gate Bipolar Transistor Temperature Celsius
Indicates IGBT junction temperature in centigrade.

Units:
Default:
Min/Max:

DegC
0.00
–/+200.00

RO

Real

943

Drive Temp Pct
Drive Temperature Percent
Indicates operating temperature of the drive power section (heat-sink) in percentage of
the maximum heat-sink temperature.

Units:
Default:
Min/Max:

%
0.00
–/+200.00

RO

Real

944

Drive Temp C
Drive Temperature Celsius
Present operating temperature of the drive power section.

Units:
Default:
Min/Max:

DegC
0.00
–/+200.00

RO

Real