Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 220

Advertising
background image

220

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Chapter 4

Port 10 and Port 11 Parameters

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

INVERTER N

Predi

ct

iv

e M

ain

127
227
327

I1 PredMainReset
I2 PredMainReset
I3 PredMainReset

Inverter n Predictive Maintenance Reset
Allows a reset of the elapsed run time to zero for either the heatsink fan or internal
stirring fans for inverter n. After the time has been reset, the value of this parameter
returns to 0 “Ready.”
“Hs Fan Life” (1) – Resets the elapsed run time (displayed in [In HSFanElpsdLif]) for the
heatsink fan on inverter n to zero.
“In Fan Life” (2) – Resets the elapsed run time (displayed in [In InFanElpsdLif]) for the
internal stirring fans on inverter n to zero.

Default:
Options:

0 = “Ready”
0 = “Ready”
1 = “HS Fan Life”
2 = “In Fan Life”

RW 32-bit

Integer

128
228
328

I1 HSFanElpsdLif
I2 HSFanElpsdLif
I3 HSFanElpsdLif

Inverter n Heatsink Fan Elapsed Life
The amount of time the heat sink fan on inverter n has been running. This value can be
reset using [In PredMainReset].

Units:
Default:
Min/Max:

Hrs
0.00
0.00 / 220000000.00

RO

Real

129
229
329

I1 InFanElpsdLif
I2 InFanElpsdLif
I3 InFanElpsdLif

Inverter n Internal Fan Elapsed Life
The amount of time the inverter stirring fans on inverter n have been running. This value
can be reset using [In PredMainReset].

Units:
Default:
Min/Max:

Hrs
0.00
0.00 / 220000000.00

RO

Real

755 (8+)
755 (8+)
755 (8+)

755 (8+)
755 (8+)
755 (8+)

755 (8+)
755 (8+)
755 (8+)

Fil

e

Gr

oup

No.

Display Name
Full Name
Description

Values

Read-W

rite

Da

ta

T

yp

e

INVERTER N

Te

st

po

in

ts

140
142
240
242
340
342

I1 Testpt Sel 1
I1 Testpt Sel 2
I2 Testpt Sel 1
I2 Testpt Sel 2
I3 Testpt Sel 1
I3 Testpt Sel 2

Inverter n Testpoint Selection 1, 2
Selects a source for [In Testpt Val n]. Used by the factory, typically for diagnostic
purposes.

Default:
Min/Max:

0
0 / 65535

RW 32-bit

Integer

141
143
241
243
341
343

I1 Testpt Val 1
I1 Testpt Val 2
I2 Testpt Val 1
I2 Testpt Val 2
I3 Testpt Val 1
I3 Testpt Val 2

Inverter n Testpoint Value 1, 2
Displays the data selected by [In Testpt Sel n].

Default:
Min/Max:

0.000000
–/+220000000.000000

RO

Real

755 (8+)
755 (8+)
755 (8+)
755 (8+)
755 (8+)
755 (8+)

755 (8+)
755 (8+)
755 (8+)
755 (8+)
755 (8+)
755 (8+)

Advertising