Drive (port 0) diagnostics file – Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 154

Advertising
background image

154

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Chapter 3

Drive Port 0 Parameters

Drive (Port 0) Diagnostics File

Fi

le

Grou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-W

ri

te

Da

ta

T

ype

DIA

G

NOSTICS

Sta

tus

930

Speed Ref Source
Speed Reference Source
Indicates the currently selected source for value displayed in P593 [Limited Spd Ref].
The Speed Reference Source displays the parameter number that is supplying the speed
reference. For example, if Speed Reference Source contains the value 546, then P546
[Spd Ref A Stpt] is the source of the speed reference.

Default:
Min/Max:

0
0 / 159999

RO

32-bit
Integer

931

Last StartSource
Last Start Source
Displays the source that initiated the most recent start sequence. All bits in this
parameter are refreshed each time the drive receives a start command.

Default:
Options:

0 = Read Only
0 = “Pwr Removed”
1-6 = “Port 1-6”
7 = “Digital In”
8 = “Sleep”
9 = “Jog”
10 = “Profiling”
11 = “AutoRestart”
12 = “Pwr Up Start”
13 = “Fault”
14 = “Enable”
15 = “Autotune”
16 = “Precharge”
17 = “Safety”
18 = “Fast Stop”
19 = “Port 13”
20 = “Port 14”

RO

32-bit
Integer

932

Last Stop Source
Last Stop Source
Displays the source that initiated the most recent stop sequence. All bits in this
parameter are refreshed each time the drive receives a stop command.

Default:
Options:

0 = Read Only
0 = “Pwr Removed”
1-6 = “Port 1-6”
7 = “Digital In”
8 = “Sleep”
9 = “Jog”
10 = “Profiling”
11 = “AutoRestart”
12 = “Pwr Up Start”
13 = “Fault”
14 = “Enable”
15 = “Autotune”
16 = “Precharge”
17 = “Safety”
18 = “Fast Stop”
19 = “Port 13”
20 = “Port 14”

RO

32-bit
Integer