Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 257

Advertising
background image

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

257

Embedded Feature and Option Module Parameters

Chapter 5

22-S

eries I/O

D

igi

tal

O

u

tpu

ts

6

Dig Out Invert
Digital Output Invert

RW 16-bit

Integer

Inverts the selected digital output.

(1) Bit 1 = “Trans Out 0” for 22-Series I/O Module model 20-750-2263C-1R2T

= “Relay Out 1” for 22-Series I/O Module models 20-750-2262C-2R and 20-750-2262D-2R

(2) Bit 2 is only used by 22-Series I/O Module 20-750-2263C-1R2T

7

Dig Out Setpoint
Digital Output Setpoint

RW 16-bit

Integer

Controls Relay or Transistor Outputs when chosen as the source. Can be used to control outputs from a communication device using DataLinks.

(1) Bit 1 = “Trans Out 0” for 22-Series I/O Module model 20-750-2263C-1R2T

= “Relay Out 1” for 22-Series I/O Module models 20-750-2262C-2R and 20-750-2262D-2R

(2) Bit 2 is only used by 22-Series I/O Module 20-750-2263C-1R2T

10

RO0 Sel
Relay Output 0 Select
Selects the source that will energize the relay output.
Any status parameter bit can be used as an output source. For example P935 [Drive
Status 1] Bit 7 “Faulted.”
For Torque Proving set to Port 0, parameter 1103 Bit 4. Use N.O. for safety.

Default:
Min/Max:

0.00 (Disabled)
0.00 / 159999.15

RW 32-bit

Integer

11

RO0 Level Sel
Relay Output 0 Level Select
Selects the source of the level that will be compared.

Default:
Min/Max:

0 (Disabled)
0 / 159999

RW 32-bit

Integer

12

RO0 Level
Relay Output 0 Level
Sets the level compare value.

Default:
Min/Max:

0.0
–/+1000000.0

RW Real

13

RO0 Level CmpSts
Relay Output 0 Level Compare Status

RO

16-bit
Integer

Status of the level compare, and a possible source for a relay or transistor output. Relay Output n Select or Transistor Output n Select must have this selected to
energize the output. Can be used without a physical output as status information only.

Bit 0 “Less Than” – Level source is less than the level value.
Bit 1 “Grt Than Equ” – Level source is greater than or equal to the level value.
Bit 2 “Abs Less Than” – Absolute value of the level source is less than the absolute value of the level value.
Bit 3 “AbsGrtThanEq” – Absolute value of the level source is greater than or equal to the absolute value of the level value.

Fi

le

Grou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-W

ri

te

Da

ta

T

ype

Options

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Tr

an

s O

ut

1

(2)

Tr

an

s O

ut

0

(1)

Rela

y O

ut

0

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Output Not Inverted
1 = Output Inverted

Options

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Tr

an

s O

ut

1

(2)

Tr

an

s O

ut

0

(1)

Rela

y O

ut

0

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Output De-energized
1 = Output Energized

Options

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

AbsG

rt

Th

anE

q

Abs L

ess

T

han

Gr

t Th

an

Eq

u

Le

ss T

han

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Condition False
1 = Condition True

Advertising