Port 10 and Port 11 Parameters

Chapter 4

Converter n (Port 11)
Parameters

Converter

n parameters apply only to PowerFlex 755 AC Input Frame 8 and

larger drives.

Fil

e

Gr

oup

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta

T

yp

e

CO

N

V

ER

TE

R

N

Sta

tus

105
205
305

C1 Fault Status1
C2 Fault Status1
C3 Fault Status1

Converter n Fault Status 1

RO

32-bit
Integer

Indicates which fault conditions currently exist for converter n. Refer to

Chapter 6

- Converter (Port 11) Faults and Alarms (Frame 8 and Larger) for information on

these fault codes.

106
206
306

C1 Fault Status2
C2 Fault Status2
C3 Fault Status2

Converter n Fault Status 2

RO

32-bit
Integer

Indicates which fault conditions currently exist for converter n. Refer to

Chapter 6

- Converter (Port 11) Faults and Alarms (Frame 8 and Larger) for information on

these fault codes.

107
207
307

C1 Alarm Status1
C2 Alarm Status1
C3 Alarm Status1

Converter n Alarm Status 1

RO

32-bit
Integer

Indicates which alarm conditions currently exist for converter n. Refer to

Chapter 6

- Converter (Port 11) Faults and Alarms (Frame 8 and Larger) for information on

these alarm codes.

755 (8+)
755 (8+)
755 (8+)

Options

Re

se

rv

ed

BF

us

eH

ar

ne

ss

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Li

ne

F

use

L3

Li

ne

F

use

L2

Li

ne

F

use

L1

LF

useH

ar

ne

ss

CT

Ha

rness

DC Bus Sh

or

t

DC Bus O

pen

Fi

rm

wa

re

F

lt

Co

mm L

oss

Po

w

er

S

up

pl

y

Br

d NT

CShor

t

Br

d NT

C

Ope

n

Br

d O

vr

Temp

HS NT

C Sh

or

t

HS NT

C Ope

n

Gr

ou

nd

F

au

lt

Ov

er

cu

rr

en

t

Si

ngl

e Pha

se

Li

ne

F

re

q

Li

ne Dip

HS Ovr

Tem

p

SCR O

vr

Temp

Pr

ec

ha

rg

e

Fa

ul

t Q

F

ul

l

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

755 (8+)
755 (8+)
755 (8+)

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Lin

e L

oss

AC

L

in

e

H

ig

h

Co

mmand St

op

BF

us

e N

eg

BF

us

e P

os

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

755 (8+)
755 (8+)
755 (8+)

Options

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Si

ngl

e Pha

se

Li

ne

F

re

q

Mini

mum

Li

ne

Li

ne Dip

Re

ser

ved

TVSS Blown

HS

O

vr

Temp

SCR O

vr

Temp

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Phase

L

ossL3

Phase

L

ossL2

Phase

L

ossL1

Pr

ec

ha

rg

e

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Advertising