286

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Chapter 5

Embedded Feature and Option Module Parameters

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

Un

iv

ersal F

eedb

ack

Encoder O

u

t

80

Enc Out Sel
Encoder Output Select
Selects the Encoder Output. If the feedback 0 or 1 device is configured as A Quad B Z then
this parameter has to be set to None. Otherwise, there is an Encoder Output Alarm (Bit
16 of [Module Sts]).

Default:
Options:

0 = “None”
0 = “None”
1 = “Reserved”
2 = “Sine Cosine”
3 = “Channel X” (FB0 Channel)
4 = “Channel Y” (FB1 Channel)

RW 32-bit

Integer

81

Enc Out Mode
Encoder Output Mode
Configures the Encoder Output type.
“A Quad B” (0) – Sets the phase relationship between the A and B signal.
“Inv A Quad B” (1) – Inverts the phase relationship between the A and B signal. Forward
and reverse exchange meanings.

Default:
Options:

0 = “A Quad B”
0 = “A Quad B”
1 = “Inv A Quad B”

RW 32-bit

Integer

82

Enc Out FD PPR
Full Digital Encoder Feedback Emulator Output Pulses Per Revolution
Specifies the emulated encoder output PPR when the Feedback Selection (FB device 0/1
Sel) is set to Full Digital (values 5…10). When the Feedback selection is set to Sin/Cos
“SC”, the Sin/Cos native PPR defines the emulated encoder outputs PPR.

Default:
Options:

1 = “1024 PPR”
0 = “512 PPR”
1 = “1024 PPR”
2 = “2048 PPR”
3 = “4096 PPR”

RW 32-bit

Integer

83

Enc Out Z Offset
Encoder Output Z Offset
Configures the offset of the Z pulse for both simulated and emulated encoder output.
The marker offset is specified within one revolution.
Simulated mode is used for full digital rotary devices and is selected by “Channel X” and
“Channel Y” in P80 [Enc Out Sel].
Emulated mode is used when “Sine Cosine” devices are selected in P80 [Enc Out Sel].
The encoder output function cannot be used with linear feedback devices.

Units:
Default:
Min/Max:

PPR
0
0 / 100000

RW 32-bit

Integer

84

Enc Out Z PPR
Encoder Output Z Pulses Per Revolution
Configures the number of Z-Pulses per encoder revolution.
For example, if “32 Z-Pulses” (5) is selected, then 32 Z pulses will be generated for each
complete revolution of the full digital input encoder. Each input encoder revolution will
produce the number of output pulses specified on the A and B output channels in
addition to 32 pulses on the Z output channel. The Z pulses will be evenly spaced
throughout the specified number of A/B output pulses.

Default:
Options:

0 = “1 Z-Pulse”
0 = “1 Z-Pulse”
1 = “2 Z-Pulses”
2 = “4 Z-Pulses”
3 = “8 Z-Pulses”
4 = “16 Z-Pulses”
5 = “32 Z-Pulses”

RW 32-bit

Integer

Fi

le

Grou

p

No.

Display Name
Full Name
Description

Values

Read-W

ri

te

Da

ta

T

ype

Un

iv

ersal F

eedb

ack

R

egi

stra

ti

on

90

Rgsn Arm
Registration Arm

RW 16-bit

Integer

Selects Registration Latches to be used.

Options

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Arm Latch

1

0

Arm Latch

9

Arm Latch

8

Arm Latch

7

Arm Latch

6

Arm Latch

5

Arm Latch

4

Arm Latch

3

Arm Latch

2

Arm Latch

1

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Condition False
1 = Condition True