Rockwell Automation Publication 750-PM001J-EN-P - October 2014

183

Drive Port 0 Parameters

Chapter 3

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

APPLIC

AT

IONS

Pump O

ff

1187

Pump Off Config
Pump Off Configure
Selects the torque data that will be used for the pump off control.
“Automatic” (0) – Downstroke torque is used if the torque waveform synchronizes with
previously saved waveform. If the position is not found after 6 cycles, the cycle torque is
used. If cycle torque is used, P1191 [Pump Off Status] Bit 3 “Cycle Used” is set to 1
“Enable.”
“Position” (1) – Downstroke torque is used to detect a pump off condition. The torque
waveform needs to be able to synchronize with the previously saved waveform.
“Cycle” (2) – Full pump cycle torque is used to detect a pump off condition.

Default:
Options:

0 = “Automatic”
0 = “Automatic”
1 = “Position”
2 = “Cycle”

RW 32-bit

Integer

1188

Pump Off Setup
Pump Off Setup

RW 16-bit

Integer

Select pump off options.

Bit 0 “Pos Filter” – Sets level of filtering on torque for position calculation: 0 = Light (Default), 1 = Heavy. Used to remove extra peaks in the waveform.
Bit 1 “Pos Offset” – Enables/disables correction factor for motor slip in position calculator. Set bit if torques and position count are drifting apart.
Bit 2 “Pos Min Trq” – Sets the minimum torque threshold for the position detector. 0 = 10% (Default), 1 = Auto Detect Min Torque.
Bit 3 “Cycle PO Pos” – Enables/disables positive level changes for Pump Off in cycle mode.

1189

Pump Off Action
Pump Off Action
Selects the action to be taken after a pump off condition has been detected.
“Change Speed” (0) – When a pump off condition is detected, speed is reduced by the
percentage set in P1196 [Pump Off Speed] and runs for the time set in P1197 [Pump Off
Time]. If condition continues, speed is reduced a second time. The pump will remain at
this speed until the pump off condition no longer exists.
“Always Stop” (1) – Stops pump when a pump off condition is detected. Pump will
remain stopped for the time set in P355 [Wake Time].
“Stop After 1” (2) – When a pump off condition is detected, speed is reduced by the
percentage set in P1196 [Pump Off Speed] and runs for the time set in P1197 [Pump Off
Time]. Pump will stop if torque continues to change while at the reduced speed. Pump
will remain stopped for the time set in P353 [Sleep Time].
“Stop After 2” (3) – When a pump off condition is detected, speed is reduced by the
percentage set in P1196 [Pump Off Speed] and runs for the time set in P1197 [Pump Off
Time]. If torque change continues, speed is reduced a second time by the same
percentage. Pump will stop if torque continues to change while at the reduced speed.
Pump will remain stopped for the time entered in P353 [Sleep Time].

Default:
Options:

0 = “Change Speed”
0 = “Change Speed”
1 = “Always Stop”
2 = “Stop After 1”
3 = “Stop After 2”

RW 32-bit

Integer

1190

Pump Off Control
Pump Off Control
Enables/Disable the pump off control or select the source for the torque level.
“Baseline Set” (1) – The control uses a torque baseline created after any start of the
drive (first ten cycles). It is critical that this data is gathered from a “full” well.
“Fixed Setpt” (2) – The control uses the value set in P1194 [Torque Setpoint]. Use the
value in P1200 [Pct Drop Torque] as a guideline in “Automatic” or “Position” mode. In
“Cycle” mode use P1198 [Pct Cycle Torque] as a guideline.

Default:
Options:

0 = “Disable”
0 = “Disable”
1 = “Baseline Set”
2 = “Fixed Setpt”

RW 32-bit

Integer

Options

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Cy

cl

e P

O P

os

Po

s M

in

T

rq

Po

s O

ff

se

t

Po

s F

ilt

er

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = Disabled
1 = Enabled