Enter pump data, Enter desired bus regulation data – Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 466

Advertising
background image

466

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

Appendix B

Application Notes

Enter Pump Data

Enter pump data and adjust parameter settings.

Enter Desired Bus Regulation Data

The following parameter settings assume that a dynamic brake resistor is used.

The following positive and negative torque limits are calculated on powerup and
entered by the drive.

P670 [Pos Torque Limit] is calculated using the motor parameters.

P671 [Neg Torque Limit] is calculated using the dynamic brake resistor
ohmic value and rated torque of the motor. If a dynamic brake resistor is
not used, the default negative torque limit is used.

Change P426 [Regen Power Lmt] to match the value in P671 [Neg Torque
Limit] to maximize dynamic brake performance.

Parameter

Setting

Pump Jack

P1178 [Motor Sheave]

Diameter in inches.

P1179 [OilWell Pump Cfg]

1 “Pump Jack”

P1181 [Gearbox Limit]

Percent of P1182 [Gearbox Rating]

P1182 [Gearbox Rating]

Nameplate gearbox rating.

P1183 [Gearbox Ratio]

Nameplate gear ratio.

P1184 [Gearbox Sheave]

Diameter in inches.

Pump Off

P1187 [Pump Off Config]

0 “Automatic” (Default)

P1189 [Pump Off Action]

Select preferred action.

P1190 [Pump Off Control]

0 “Disable” (Default)

Parameter

Setting

Braking Features

P372 [Bus Reg Mode A]

2 “Dyn Brake”

(1)

(1) If no dynamic braking resistor is used, set P372 [Bus Reg Mode A] to 1 “Adjust Freq” (Default).

Speed is sacrificed for bus regulation and P524 [Overspeed Limit] needs to be adjusted.

P382 [DB Resistor Type]

1 “External”

P383 [DB Ext Ohms]

Based on performance preference.

P384 [DB Ext Watts]

Based on performance preference.

P385 [DB ExtPulseWatts]

Based on performance preference.

Motor Overload

P409 [Dec Inhibit Actn]

0 “Ignore”

Load Limits

P426 [Regen Power Lmt]

Set to match the value that is calculated for P671 [Neg Torque Limit], see
below.

Advertising